Seitenansicht 5
Digital Fiber Sensor FX-100 SERIES
128
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
Fiber Sensor
Amplifiers
FX-300
FX-100
Fibers
FT / FD / FR
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
FIBER
SENSORS
FX-100
Fiber Sensor
Ampli ers
LIST OF FIBERS
Fibers are listed in alphabetic order. Refer to p.63~ “Fiber Selection” for details of each ber.
Retrore ective type
Model No.
Sensing range (mm
in) (Note 1, 2)
Dimensions
Standard type FX-101
Long sensing range type FX-102
FR-KV1
15 to 200 0.591 to 7.874 15 to 360 0.591 to 14.173 P.112
FR-KZ21
200 7.874 200 7.874 P.112
FR-KZ21E
200 7.874 200 7.874 P.112
FR-WKZ11
100 to 550 3.937 to 21.654 100 to 830 3.937 to 32.677 P.112
2)
The sensing range of FR-WKZ11 is the possible setting range for the re ector or re ective tape. The ber can detect an object less than 100 mm 3.937 in away.
However, note that if there are any white or highly-re ective surfaces near the ber head, re ected incident light may affect the ber head. If this occurs,
adjust the threshold value of the ampli er unit before use.
The sensing range of FR-KZ21(E) is the possible setting range for the re ector. However, if setting the ber to detect objects passing within 0 to 20 mm
0 to 0.787 in from the ber head, unstable detection may result.
The sensing range of FR-KV1 is the possible setting range for the re ector. The ber can detect an object less than 15 mm
0.591 in away.
Re ective type
Fibers are listed in alphabetic order. Refer to “Fiber Selection p.63~” for details of each ber.
Model No.
Sensing range (mm
in) (Note 1, 2)
Dimensions
Standard type FX-101
Long sensing range type FX-102
FD-A15
125 4.921 250 9.843 P.113
FD-AFM2
105 4.134 285 11.220 P.113
FD-AFM2E
85 3.346 245 9.646 P.113
FD-B8
170 6.693 440 17.323 P.113
FD-E12
3.5 0.138 13 0.512 P.113
FD-E22
16 0.630 45 1.772 P.113
FD-EG1
18 0.709 50 1.969 P.113
FD-EG2
10 0.394 30 1.181 P.113
FD-EG3
7 0.276 22 0.866 P.113
FD-EN500S1
1 0.039 4 0.157 P.113
FD-ENM1S1
15 0.591 48 1.890 P.114
FD-F4
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm
ø0.236 to
ø1.024 in
transparent pipe
[PFA ( uorine resin) or equivalently
transparent pipe, wall thickness 1 mm
0.039 in]
P.114
FD-F41
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm
ø0.236 to
ø1.024 in
transparent pipe
[PVC (vinyl chloride), uorine resin,
polycarbonate, acrylic, glass, wall
thickness 1 to 3 mm
0.039 to 0.118 in]
P.114
FD-F8Y
P.114
FD-FM2
100 3.937 410 16.142 P.114
FD-FM2S
100 3.937 345 13.583
P.114
FD-FM2S4
P.114
FD-G4
50 1.969 120 4.724 P.114
Model No.
Sensing range (mm
in) (Note 1, 2)
Dimensions
Standard type FX-101
Long sensing range type FX-102
FD-G6
50 1.969 120 4.724 P.114
FD-G6X
45 1.772 160 6.299 P.114
FD-H13-FM2
100 3.937 280 11.024 P.114
FD-H18-L31
0 to 10 0 to 0.394 0 to 25 0 to 0.984 P.115
FD-H20-21
90 3.543 280 11.024 P.115
FD-H20-M1
120 4.724 300 11.811 P.115
FD-H30-KZ1V-S (Note 3)
25 to 80 0.984 to 3.150
10 to 220 0.394 to 8.661
P.115
FD-H30-L32
2 to 9 0.079 to 0.354
0 to 17 0 to 0.669 P.115
FD-H30-L32V-S (Note 3)
2.5 to 6.5 0.098 to 0.256
0 to 11 0 to 0.433 P.115
FD-H35-20S
85 3.346 200 7.874 P.116
FD-H35-M2
75 2.953 280 11.024
P.116
FD-H35-M2S6
P.116
FD-L4
5 to 8 0.197 to 0.315
(Convergent point 6 0.236)
1 to 17 0.039 to 0.669
(Convergent point 6 0.236)
P.116
FD-L41
3 to 14 0.118 to 0.551
(Convergent point 8 0.315)
1.5 to 16 0.059 to 0.630
(Convergent point 8 0.315)
P.116
FD-L43
0 to 19 0 to 0.748 0 to 25 0 to 0.984 P.116
FD-L44
0 to 6 0 to 0.236 0 to 8 0 to 0.315 P.116
FD-L44S
0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217 P.116
FD-L45
0 to 40 0 to 1.575 0 to 50 0 to 1.969 P.116
FD-L46
16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969
P.116
FD-NFM2
35 1.378 100 3.937
P.117
FD-NFM2S
P.117
FD-NFM2S4
P.117
FD-P2
25 0.984 65 2.559 P.117
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the bers. Refer to p.71~ for details.
2) Please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) Sold as a set comprising vacuum-resistant type ber + photo-terminal (FV-BR1) + ber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Notes: 1) Please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
The sensing range of FR-WKZ11 is speci ed for the RF-13. The sensing range of FR-KZ21, FR-KZ21E and FR-KV1 is speci ed for the attached re ector.
The sensing ranges when using in combination with the FR-WKZ11 re ector (optional) are given in the below table.
Ampli er
Re ector
FX-101 FX-102
FR-WKZ11 + RF-210
100 to 700 3.937 to 27.559 100 to 1,100 3.937 to 43.307
FR-WKZ11 + RF-220
100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362
FR-WKZ11 + RF-230
100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480