HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix B Revision 8
B–8
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codesi.e., ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Force Back-Up
State
FBU=
1 byte,
value of 0, 1, 2
Command or Query.
For 1:2 systems only (sent only to the BU unit).
Force one of the online units to be a backed up for maintenance and test purposes, in the form
x, where:
0 = Force BU OFFLINE and place system in AUTO mode.
1 = Force SSPA 1 OFFLINE and place system in MANUAL mode.
2 = Force SSPA 2 OFFLINE and place system in MANUAL mode.
FBU=
FBU?
N/A
N/A
Online Status
N/A
1 byte,
value of 0,1
Query only.
For 1:1 systems only (sent to both units).
Returns the online status in the form x, where:
0 = OFFLINE
1 = ONLINE
ONL=
ONL?
ONL?
ONL=x
(see Description of
Arguments for
details)
Configure
Redundancy
Amp
CRA=
1 byte
value of 0,1
Command or query.
Permits configuration of the redundancy amplifier mode in 1:1 and 1:2 redundancy systems, in
the form x, where:
0 = Disabled - the offline unit's amp state will follow the online unit's amp state (Default).
1 = Enabled - the offline unit's amp state will be Off, if it becomes the online unit, then its amp
state will be On. This affects all units in the redundancy system.
Note: The same CRA value should be sent to all units in the redundancy system.
CRA=
CRA?
CRA?
CRA=x
(See Description of
Arguments)
Redundancy
Mode
RAM=
1 byte,
value of 0,1
Command or Query.
For 1:1 systems only (sent to both units).
Sets or returns redundancy mode in the form x, where:
0 = MANUAL
1 = AUTO
RAM=
RAM?
RAM?
RAM=x
(see Description of
Arguments for
details)
Redundancy
State
N/A
1 byte,
value of 0, 1, 2
Query only.
Returns the current redundancy state in the form x, where:
0 = OFF
1 = 1:1 Redundancy
2 = 1:2 Redundancy
N/A
RED?
RED=x
(see Description of
Arguments for
details)
Set switch
position
SSW=
1 byte,
value of 0,1
Command only.
For 1:1 systems only(sent to either unit):
Only used when system is in MANUAL redundancy mode (RAM=0, both units).
Forces switch position in the form x, where:
1 = Forces switch to put SSPA 1 online
2 = Forces switch to put SSPA 2 online
SSW=
SSW?
N/A
N/A
Gain Offset
GOF=
5 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:1 redundancy system
so power is equal between the online and offline units when a switchover occurs, in the form
xx.xx.
Example: GOF=02.00’cr’
GOF=
GOF?
GOF*
GOF?
GOF =xx.xx
(See Description of
Arguments for
details)