HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Serial-Based Remote Product Management Revision 8
5–13
Parameter
Type
(Instruction
Number of
Arguments
Description of Arguments
Response to
Command
(Instruction
Response to Query
Status
alphanumeric
Reports the Maintenance status of the unit. Response is comma delimited in the form aaaa,bbbb,ccc,’cr’’lf’
where:
aaaa = Remote Unit Address
bbbb = Remote Baud Rate
(See Description of
Arguments)
Time-Clock)
Date
numeric
Set clocks in the form mmddyy, where:
mm = month of the year, between 01 and 12
dd = day of the month, between 01 and 31
yy = year, between 00 and 96 (2000 to 2096)
Example:(date = April 24, 2003):
<1/DAT=042503’cr’
DAT?
DAT*
(See Description of
Arguments)
Firmware
Number
Returns the firmware type loaded into the unit.
Example: <1/FRW?’cr’
>0001/FRW=’cr’
BULK=FW12524’cr’
MnC =FW12522’cr’
FPGA=FW10788’cr’’lf’
Note: the RET? Query returns the MnC firmware revision.
(See Description of
Arguments)
value of 0,1
Mutes the unit, in the form x, where:
0 = Disabled
1 = Enabled
2 = Unit muted due to discrete control lines. Query response only.
MUT?
MUT*
(See Description of
Arguments)
value of 0, 1
Online status (applies only to redundancy), in the form x, where:
0 = Disabled
1 = Enabled
Example: <1/ONL=1’cr’
ONL?
ONL*