6
ELECTRICAL
WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED ON
THE TOP OF THE CONTROL BACK COVER.
A 13 amp 230v ~ 50 Hz fused electrical supply is required adjacent to the appliance. External wiring to the unit must be
installed using a 3 core silicon - SIHF insulation cable, and in accordance with the current wiring regulations and any local
regulations which apply.
The method of connection to the mains electricity supply must facilitate complete electrical isolation of the appliance,
preferably by a fused double pole switch, having a contact separation of at least 3mm in both poles.
A 13A safety plug can be used, however, we do strongly recommend connection via a fused double pole switch for integrity
of the connection. If a 13A safety plug is used it must be of a high quality and must be to BS1363 - 3: 1995 (13A Plugs,
socket, outlets and adaptors).
NOTE: Switched spur outlet should only serve the appliance.
The isolator should not be positioned immediately above the cooker, but must be fitted within 1.5 metres of the cable exit
point of the appliance.
ELECTRICAL TEST PROCEDURE
Final Electrical Test using (CLARE) and Flash Test
Flash Test Procedure
(Earth Appliance Test Simulation)
1. Select 1250v Flash Test on Clare Test equipment.
2. Plug the 13 amp supply plug into the test equipment.
3. Depress the red ‘Test Button’ for 3 seconds.
4. A ‘Pass’ light will illuminate.
5. If the appliance fails the test, re-check all circuits and correct the fault and re-test the appliance.
6. Disconnect from the test equipment and connect cooker to its permanent supply.
7. A full load test will be performed using a clamp meter connected to the incoming supply.
NOTE: The test results 10.5/11 amps normal operation.
8. Make notes of results and disconnect all leads.