Revision 1.9 - 32 -
6.9
Control board plug setup (Easy move model)
STOP
START
FOOT
CONTROL
SLIDE VALVES
POWER PACK
GROUND for PC BOARD
CIRCUIT BOARD K+
SECONDARY HARNESS
for SLIDE function
POSITIVE for PC BOARD
(black #2 to 2
and black # 4 to 27)
CYLINDERS
LIFT 15 (2 ea)
PUSH-PULL
CYLINDERS
CONTROL PANEL
JUMPER
Easy move
Proximity
Switch
WIRELESS CONTROL
Figure 29 Plug setup on PC - Board
This graphic describes the different functions of each plug and where it is connected to. Make sure every
plug is in its correct position and fuses are in good conditions.
Connector description:
J-1: Main power input and connection to pump & motor tray
J-1: Connection on “2”, “-“ and “E” for Easy move proximity switch
J-2: Ground connection
J-3: Platform equipment (foot controls)
J-30: Control panel
J-32: Control panel input for slide function
J-4: Lift cylinder- (#15)
J-41: B-15 Lift arm sensor for Easy move platform position control
J-42.1: Output to Slide valves S-7 (slide in) and S-8 (slide out)
WARNING
LIGHTS