8-12. Second Auxiliary Power Supply Circuit
The second auxiliary power supply circuit need to activate IC651. When the power switch is turn on, the
current flows into IC651 pin3.
And the current which flowed out from IC651 pin1 charges C653.
Oscillation starts when the voltage of IC651 pin 1 reaches about 6V by this action.
After start of oscillation, the fly-back voltage of the auxiliary winding of T651 is rectified and smoothed by
D651,R651 and C651.
The resulting DC voltage is supplied to IC651 pin 1.(Then current frows in into IC651 pin 1.)
(Fig.8-13) Second Auxiliary Power Supply Circuit
8-13. Second Converter Circuit
The second converter circuit consists of the primary winding of T651,
a switching device MOSFET(internal IC651) and surge absorbers (C656,C660,R659,R660 and D653)
which are connected to the primary winding of T651.The feedback current to control “ON Duty” flows in
into IC651 pin 1. so that the collector-emitter is turned ON and OFF.
IC651 pin 1 is also used as the connection to provide internal bias current.
(Fig.8-14) Second Conveter Circuit
D601(+)
T651
C609
+
-
D651
PC651
R658
R657
C653
C654
+
-
C651
+
-
R651
DRAIN
CONTROL
IC651
SOURCE
1
2
3
C610
+
-
D601(+)
C609
+
-
T651
R659
R657
R660
C660
C656
D653
IC651
Feedback Current
C653
+
-
PWM
Control
Circuit
C
1
S
2
D
3
C610
+
-
Seitenansicht 175