5-3
User MODE: Auto EMF function is on.(LED is green)
Auto EMF function on -> off
a. Open the MENU (U),TAG7)-
DISPLAY MODE
, and Press
+
and
switch at once.
b. Then
DEGAUSS OK
appear on OSM, and AUTO EMF function is
on state.
When push any switch and power on/off, AUTO EMF function become
off state.
But when receive frequency change, AUTO EMF function stay on state.
5) After sufficiently degaussing the CRT, move degaussing coil slowly away from the panel surface while
rotating from corner to center, taking more than 3 seconds.
Turn off SW more than 1 m away from the CRT. Degauss again if the unit is gassed.
6) When aperture grille get entangled while degaussing, receive the signal of 1dot alternate pattern and
degauss again. If aperture grille remain entangled, Put vibrate from side.
5. Signal Generator
LVG-1603 is recommended for signal generator.
Use calibrated signal generators. However, use VG-819 in focus regulation.
Note) Adjustment timings are timing tables and are not programmed timing.
6. Color Analyzer, Convergence Meter, Landing Mater
The color analyzer should be CA-100 (made by MINOLTA) or compatible.
The convergence meter should be CC-100 (made by MINOLTA) or compatible.
The Landing meter should be KLD-01 (made by KAMAYA) or compatible.
Over 1m
SW OFF
Magnetized Pattern Example