Caple C702G Wartungshandbuch Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 286
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
5-1
ADJUSTMENT PROCEDURES
Application
These specifications outline the adjustment procedures for Model FP1370 (A)/(B) 22-inch color monitor.
Model Name: FP1370 (A)/(B)
Destination: North America, Europe Standard Adjustment Conditions
Standard Adjustment Conditions
1. Power Supply Voltage
A / B Version: AC 100V±5% 50/60Hz or AC 120V±5% 60Hz or
AC 220V±5% 50Hz
2. Warm Up
Adjust this monitor after a minimum of 90 minutes to allow unit to reach ambient operating temperature.
(Use the Self Test screen. Refer item 7-5-3. about Self Test. )
Adjust the monitor according to item
Rough Adjustment before warm up
before warm up.
When aging, cover with back cabinet or aging jig.
3. Signals
Unless otherwise specified, adjustment should be Mini D-SUB 15 pins.
Video: Analog 0.7±0.01 Vp-p Positive polarity (terminated at 75 ohms±1%)
or Analog sync. on green
Video 0.7±0.01 Vp-p positive polarity
Sync 0.3±0.01 Vp-p negative polarity
(terminated at 75 ohms ±1%)
Sync.: TTL level (High level : more than 2.4V / Low level : less than 0.8V)
H/V separate, positive / negative polarity
or H/V composite, positive / negative polarity
or Sync. on green, 0.3±0.01 Vp-p negative polarity
(terminated at 75 ohms ±1%)
Seitenansicht 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 285 286

Kommentare zu diesen Handbüchern

Keine Kommentare