5
The hob must be installed by a
qualified technician and in
compliance with local safety
standard.
Take care not to lose or mishandle
any parts when unpacking the
appliance.
Positioning the appliance
The hob must be installed a
minimum of 50 mm from the back
wall and 150 mm from any vertical
surface either side of the hob.
Adjacent units must be a
minimum of 450 mm above the
worksurface.
If you are installing a cooker hood
above the hob there must be a
minimum height of 750 mm
between the appliance.
If a cooker hood is not installed,
there must be a minimum height
of 900 mm between cabinets
above the hob.
This hob must not be installed
above refrigeration products.
Fig. 2
Ventilation
All rooms require a window which can be opened or equivalent, while some rooms
require a permanent vent in addition to a window.
This unit must not be used in a room with less than 5 m
3
.
Room Volume Air vent necessary (effective area)
5 m
3
100 cm
2
5 m
3
to 10 m
3
50 cm
2
Greater than 11 m
3
No air vent necessary
A room 5 m
3
to 10 m
3
with a door
No permanent air vent necessary
opening to the outside
The above requirements allow use of a gas oven and grill but if there are other fuel
burning appliances in the same room BS5440 part 2: 1989 (ventilation) should be
consulted to determine the necessary air venting requirements.
Installation