Apple II Computer Info
strengthens the wires and crimp pins. It is flexible, so just bend the
wires slowly as they are positioned in the IIgs casing.
13. Does plug insertion endanger the male pins of the motherboard IIgs
connector? This is doubtful; All the power supplies are pretested prior
to shipment on my two IIgs systems at home. Each motherboard power point
has had MANY power supplies connected, and no pins have been broken yet.
TROUBLE-SHOOTING TIPS
HHHHHHHHHHHHHHHHHHHHH
PROBLEM COMMENTS / WHAT TO DO
============================================================
=============== UNIT DOES NOT POWER-UP. 1. Check power switch: "|" is
on, "0" is off.
2. Try a different AC power cord; internal crimps
on the AC power cord's female connector may be
spread too wide to make good contact with the
power unit's male input prongs.
3. Shake the power supply and listen for rattling
sound. Rough handling during shipment may
have
shaken loose the internal fuse. (Fuse is
soldered to holder in half the power units,
but
is clamped in place in half the units.)
4. Fuse may have blown; must be inspected
visually
by opening the case with power cord unplugged.
5. Use caution if testing voltages with standard
voltmeter probes inserted into IIgs female
Molex-7 plug, or into IIe female AMP-6 plug.
Voltmeter probes are too wide for the crimp
pins, and will spread the crimps, causing poor
contact on the motherboard connector. Safe
way
to test voltages is to insert short length of
paper clip into the plug, then touch voltmeter
probe to paper clip metal. Alternatively, IIgs
Molex-7 plug has exposed metal strips on its
back side on which voltmeter probes can be
safely touched.
UNIT STARTS BUT SHUTS 1. Half the units have "no-load auto-off"
OFF IMMEDIATELY. protection circuit, which shuts off power
immediately if no load is connected. If power
supply has this feature, the phrase is etched
near the power switch. Voltage can be tested
by connecting a load (such as a hard drive) to
a
Molex-4 connector; fan will spin and voltages
can be tested.
UNIT POWERS-UP BUT 1. This is more often a problem with IIgs ROM 3
than
APPLE THEN CRASHES with IIgs ROM 1 or with IIe. Some large power
IMMEDIATELY. supplies have a slower "rise-time" to their
target voltages. Solution is to do a "warm
Apple II Computer Technical Information : Apple II Family Hardware Info